GENERAL SPECIFICATIONS
Hold-up time
Efficiency
isolation voltage
Switching frequency
Safety Approvals
Maximum weight
120 Vac, 60 Hz
120 Vac 30 W output
input to ouput
input to ground
fixed
16 ms at 30 Watts output
>78 %
4000 Vac
1500 Vac
120 KHz, +/- 5 KHz
UL/EN/IEC 60601-1 CSA22.2 No.601
UL/EN/IEC 60950-1 CSA22.2 No.60950-1
100 g (0.22 lbs)
MODEL NUMBER 40 o C Convection 50 o C Convection
50 o C Airflow
RIPPLE
REGULATION
GNT30-5
GNT30-12
GNT30-15
GNT30-24
GNT30-28
GNT30-48
5 V 4.0 A
12 V 2.5 A
15 V 2.0 A
24 V 1.25 A
28 V 1.07 A
48 V 0.625 A
5 V 3.2 A
12 V 1.66 A
15 V 1.06 A
24 V 0.83 A
28 V 0.8 A
48 V 0.416 A
5 V 6.0 A
12 V 2.5 A
15 V 2.0 A
24 V 1.25 A
28 V 1.07 A
48 V 0.625 A
50 mV
120 mV
150 mV
240 mV
280 mV
480 mV
2%
2%
2%
2%
2%
2%
NOTES
1. When the input voltage is less than 90 Vac the operating temperature range is 0 o C to 40 o C. The ripple and regulation
specs. may not be met.
2. Peak output current rating is for 1 minute and 10 % duty cycle.
3. Heatsink temperatures should not be allowed to exceed 90 o C
4. Output Voltage is adjustable +/- 5% of nominal. See installation instructions (www.condorpower.com)
MECHANICAL NOTES
INPUT
J1 AMP P/N 640456-3 TB1
PIN 1 AC LINE
PIN 2 N/C
PIN 3 AC NEUTRAL
PIN 1 AC LINE
PIN 2 AC NEUTRAL
0.187 Faston
GROUND
GROUND
OUTPUT J2 AMP P/N 640456-4 TB2
PIN 1 COMMON
PIN 2 COMMON
PIN 3 OUTPUT 1
PIN 4 OUTPUT 1
PIN 1 COMMON
PIN 2 OUTPUT 1
MATING CONNECTORS
CONTACT
INPUT
OUTPUT
HOUSING 1375820-3
HOUSING 1375820-4
1375819-1
1375819-1
Condor DC Power Supplies Inc. 2311 Statham Parkway, Oxnard CA, 93033, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: condor@condordc.com
GNT30 Rev H 11/11/05.
Data Sheet ? 2005 Condor DC Power Supplies Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no
responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.